â² JHM-2028 main technical parameter
|
|
â Volume (length× width ×height): ·370mm×340mm ×1570mm â Weight: about 90kg ãã â Power supply voltage: AC220V±10% ãã ·Frequency: 50HZ ~ 60 HZ ·Power: 1500W â Blood pump/spare pump: ·Flux: 15 ~ 340ml/min (Ф 6mm) 20 ~ 460 ml/min (Ф 8mm) â Heparin pump: ·Flux: 0.1ml/hï½10ml/h(±5%) ·Precise: 0.1ml/h ·Injector size: 20ml/30ml/50ml 10ml/20ml/30ml (selectable) â Arterial pressure: ·display scope:-300mmHgï½+300mmHg (±10mmHg) â Venous pressure: ·display scope:-50mmHgï½+300mmHg (±10mmHg) â Dialysate flow: ·300ml/minï½800ml/min linearity adjustable (+10%)
(-5%) ·Temperature:35.0â~39.0â ·Resolving rate:0.1â ·Conductivity:13mS/cm~15.5mS/cm (±0.1 mS/cm)
·Conductivity:13mS/cm~15.5mS/cm (±0.1 mS/cm)
·Conductivity:13mS/cm~15.5mS/cm (±0.1 mS/cm)
·Conductivity:13mS/cm~15.5mS/cm (±0.1 mS/cm)
|
â UF flow scope: 0ï½1800ml/h(±30ml/h ) 0ï½4000ml/h(optional) â ISO UF flow scope:0ï½2000ml/h(±30ml/h) â TMP ·Scope:-100mmHgï½+600mmHg (±20mmHg) â Blood leakage monitor: ·over 1ml blood per liter dialysate (flow:500ml/min) â Blood level monitor: ultrasonic sensor â Air bubble monitor: ·Infrared and response threshold value: Single air bubble of 200 и I exists when Blood flux is 200ml/min â Inflow pressure:0MPaï½0.6MPa â Inflow temperature: 5âï½30â â Environment temperature: 10âï½30â, · Relative humidity≤70% â Rinse/disinfection: chemical disinfection (citric acid,peracetic acid and oxalic acid) â Hot rinse: 80â â Back-up power supply: last for 15-30min after electric-cut.
|
|
| â² JHM-2028 function |
|
Be applicable of hemodialysis treatment,hemoperfusion,Plasma Exchange,Pure ultrafiltration project.Touch screen was equipped and it can show Naï¼and UF profiles;In addition,the functions ie.backup power supply, Kt/V,HCO3Ë adjustment,single needle,acetate treatment,pyrogen filter port and net connection ect.are optional.
|
|
â² Clinical Application
|
|
â Hemodialysis Therapy:same as JH-2000 â Pure ultrafiltration Therapy: same as JH-2000 â Hemoperfusion Therapy:same as JH-2000 â Plasma exchange Therapy:same as JH-2000 â Naï¼and UF profiling: ·Be applicable for reducing the cases during dialysis treatment such as low/high pressure,muscle convulsion, headache,nausea,vomit ect. â Kt/V function: ·The sufficiency of dialysis can be reflected by Kt/V.(Optional) â HCO3 adjustment function: ·Be applicable for sericous acid toxicosis patient. Be capable to calibrate the acid toxicosis status according to patient's state of illness.(optional) â Backup power-supply: ·It can last for 15-30 minutes after power cut off. â Pyrogen filter port: Completely filtrating the remained bacteria and endotoxin.(optional) â Net connection: One computer can audit and control the treatment of maximum 20 units hemodialysis machine (optional)
|
|
|
|
|
|
| |
|
|
|